External Lightning Protection
External Lightning Protection is a necessity. Lighting, a natural phenomenon cannot be avoided but can be protected against. Two types of external lightning protection namely Advanced Lightning Prevention also called Early Stream Emission (ESE) and Advanced Lightning Capture System also called Dissipation Array System (DAS) are available. Protection is available against direct lightning. The equipments are capable of handling multi strikes of lightning of the order of 200KA at 10/350 microseconds waveforms. Dissipation of this energy to earth is done through low impedance copper down conductor & maintenance free earth pits.
Easy Stream Emission (ESE)
ESE is a innovative external lightning
protection device, which is radio quiet and is active only during
the lightning event. The system comes in two pieces which are put
together and then mounted on a Mast with the help of an adapter. It
can be installed on a tower, rooftop or on the sidewall of the
building. The adapter provides for the fixture of the Down
Conductor. A Lightning Counter is positioned in a manner through
which the Down Conductor passes en-route to the pit. The Lightning
Counter is positioned at a height just above the guard pipe, so that
it can be can be easily monitored.
Dissipation Array Terminal
We offer Dissipation Array Terminal that
prevents lightning strikes, by reducing the local, storm-induced
electric fields and hence protecting the area. Prevention from
direct strikes also eliminates many secondary effects. These highly
efficient DAT systems with grounding and surge technologies provide
complete protection from lightning and other electrical phenomena.
It also reduces the risk of electrical impulses on electrical
service lines and control lines. Our Dissipation Array Terminals are
available in different configurations, so that they can provide
protection from lightening to structures in any industry. Common DAT
application areas include buildings, utility towers, storage tanks,
smoke stacks, offshore facilities etc.
Internal Lightning Class B Protection
We are the leading manufacturers & exporters of Internal Lightning Class B Protection. Class B protection is for electrical & sensitive electronic devices against surge voltage. It is capable of handling surges of the order of 50KA at 10/350 using fuse less surge arrestor. The multistrike handling system, the operation is regulated by using an energy coordination coil.
Class C Protection
Class C Protection is capable of handling surges of the order 40KA at8/20 micro second with the help of fuse less surge arrestors. The multi-strike handling system operation is regulated by using an energy coordinated coil.
Telephone Line Protection Equipment
These are plug-in surge arrestors that protect communication network using line systems. These are designed using insulation pierced connections that have built- in fail-safe overload protection and surges up to 10 KA (average) at 8/20 microseconds
The device provides four stage protections with combinations of GD Tube, MOV's, PTC and Surge suppressor diodes. The device operates in a fraction of a second with operating temperature range of 25C to + 80 C. It provides protection in four areas:- Radio Frequency Interface Protection, Computer Network Protection, Coaxial Cable Line protection and Data Line and server Protection.
Earthing Products
Good earth pits as specified by BIS /
IEC are made using Copper Plates/Rods or GI Plates/Pipes. They are
dug deep in the ground in different combinations. Earth Conductivity
Enhancement Compound is used to make the pit the pits are
maintenance free, as well as improve the soil conductivity by 3 –
20 times. Pits with low resistance, 2.0 ohms for lightning and less
than 1ohm for equipments are recommended. The maintenance free
earthing is advantageous as water pouring at regular intervals is
not required, because it retains the moisture. It also maintains
almost the same earth resistance value, regardless of soil and
climatic condition.
**Features**
- Copper Clad MS electrode technology
- Copper bus bars for excellent conductivity
- Earth resistance value improves with time
- Requires less space and time to install the earthing
electrode