Home·THERMO FOAM INDUSTRIES PRIVATE LIMITED·Products·Calcium Silicate Insulation

Calcium Silicate Insulation

Certificates:Class 1 for surface spread of Flame CharacteristicsClass ‘O’ for Fire PropagationFire-rated “CLASS O”Class 0 complied+2 more
THERMO FOAM INDUSTRIES PRIVATE LIMITEDChennai, TN
Storefront
Anchored to the MCA registerCIN U33111TN1979PTC007925
Price on request. Ask the factory for a quote.
MOQ not stated Lead time on requestCurrency INR
Key attributesAll specs
Category
Calcium Silicate Insulation
Place of origin
Chennai, TN, India

Highlights at a glance

  • Category: Insulation Products
  • Made in Chennai, TN, India
  • Certified: Class 1 for surface spread of Flame Characteristics, Class ‘O’ for Fire Propagation, Fire-rated “CLASS O”

Description

The raw material of Thermofoam calcium silicate board is high-purity quartz flour, high-grade portland cement,high-purity slaked lime, plant fiber, and other mineral added substances. Thermofoam calcium silicate board is for indoor partition and ceiling of moisture-proof and fireproof in the wet area building for both civil and industry application. So Calcium silicate board whose main component is just this kind of crystalloid, has good fire retardancy, water resistance, high strength, durability, and so on.

FEATURES

  • 100% Asbestos Free
  • Fire Resistance and Moisture Resistance
  • High Strength and Good Stability
  • Anti Fungus and Antiseptic
  • Widely used in Partition and Suspension System.
  • Easy working
  • Anticorrosive

CEILING INSTALLATION METHOD

1. Carry out ceiling line-measuring to determine the ceiling’s fixed position, the boom’s central range is generally 1200. 2. Connect and fix the boom and main keel with a hanging piece to make the main keel keep its level position. 3. Vertically fix the sub-keel to the main keel with the hanging piece; the sub-keel axis central range is 612mm. 4. Install the laterally supporting keel properly, its central range is 1224mm. 5. Fix the board on sub-keels with tapping screws, and to well the seam-connecting treatment.

Thickness(mm)

5/6

SIZE

Width(mm) 595/603 Length(mm) 595/603

Weight(kg/pcs)

3.50

PARAMETERS

Deviation in thickness: ±0.5mm Bending strength: ≥ 12MPa(EMC) Moisture content: ≤ 10% Thermal Conductivity: ≤ 0.3W/(m.K) Temperature resistance ±120 Celsius Density Density: 1100—1300kg/m3 Modulus of Elasticity: 7100±500MPa(Wet) Wet expansion: ≤ 0.2% Frost Resistance: -30 Celsius Incombustibility A grade fireproof

NOTICE

The hanging system of Thermofoam board combined with light steel keel is divided into two kinds of person-standing type and non-person-standing type; for the non-person-standing type, only consider the self-weight of ceiling and light. Lamp without loading other loads; for the person-standing type. Consider about 80~100kg load when someone repaired it.

Insulation thickness (mm)

50 75 100

Range of R-value (Thickness/Conductivity) * in SI and PI unit [ R-SI in m2.K/W and R-PI in sq.ft.F.Hr./Btu]

85 - 89% 90 - 93% 92 - 94%

Roof U-value range in SI and PI unit [U-SI in W/m2.K and U-PI in Btu/sq.ft.F.Hr]

85 - 89% 90 - 93% 92 - 94%

Insulation efficiency in percentage [ {U(uninsulated)-U(insulated)}/ U(uninsulated) x 100]

85 - 89% 90 - 93% 92 - 94%
  • Fire-rated “CLASS O”
  • Very low water vapor permeance (0 perms)
  • High water vapor diffusion factor (> 17,000)
  • The very low water absorption rate (0.06% by volume)
  • High thermal efficiency (λ24˚ C = 0.033 W/mK; λ46˚ C = 0.035 W/mK)
  • Wide temperature range (from -50˚ C to +105˚ C)
  • Chemical resistance – Resistant to most chemicals (sodium, silica, fluoride, chloride, etc.)
  • Antibacterial & antifungal
  • Environmental friendly – ODP = 0 and GWP < 5
  • Very low VOC emission level ( < 6 µg/m2/hr in 24 hours)
  • Sound absorption properties
  • Perfect fit to most of the pipe sizes
  • Easy and fast to install

Certificates

Class 1 for surface spread of Flame Characteristics
Class ‘O’ for Fire Propagation
Fire-rated “CLASS O”
Class 0 complied
BS (British Standard) 476 part 4, ISO 1182, IS 3808, International Maritime Organization (IMO) - NON-COMBUSTIBLE
Reaction to fire A1 as per EN 13501
BS 476 part 6 – Does not PROPAGATE FIRE
BS 476 part 7- Class 1 - SURFACE SPREAD OF FLAME is NIL
BS 476 part 5 – Designated as P - (not easily ignitable)
BS 6853 (toxicity index 0.65) - NON-EMISSION OF SMOKE and TOXIC GASES
Dubai Civil Defense (DCD) Certified
Class ‘O’ Fire Rated
Incombustibility A grade fireproof

Reviews

Reviews here are order-verified. Only buyers who completed a delivered order can rate this supplier, so the first review appears after the first delivery on BharatSeal.

Questions & answers

Ask the supplier. Answers are visible to all buyers

No questions yet. Ask the first one: the supplier is notified and the answer is posted here for every buyer.

Know your supplier

THERMO FOAM INDUSTRIES PRIVATE LIMITED
Unverified<1 yr on BharatSealChennai, Tamil Nadu
Year founded
2021
Certifications
13

More from Thermo Foam Industries

Similar products from other suppliers

Rock Wool
IS standards

Rock Wool

Price on request
GJ
SRI BHAVANI CERAMIC PRIVATE LIMITED· Bharuch
Ceramic Fiber Blanket
IS standards

Ceramic Fiber Blanket

Price on request
GJ
SRI BHAVANI CERAMIC PRIVATE LIMITED· Bharuch
PUF Boards And Pipes
IS standards

PUF Boards And Pipes

Price on request
GJ
SRI BHAVANI CERAMIC PRIVATE LIMITED· Bharuch
Glass Wool
IS standards

Glass Wool

Price on request
GJ
SRI BHAVANI CERAMIC PRIVATE LIMITED· Bharuch
Aluminium Sheet And Coil
IS standards

Aluminium Sheet And Coil

Price on request
GJ
SRI BHAVANI CERAMIC PRIVATE LIMITED· Bharuch
Thermocol EPS Sheets and Pipes
IS standards

Thermocol EPS Sheets and Pipes

Price on request
GJ
SRI BHAVANI CERAMIC PRIVATE LIMITED· Bharuch
Insulation Products

Insulation Products

Price on request
68 yrsMH
GOLD SEAL ENGINEERING PRODUCTS PRIVATE LIMITED· Mumbai
Nitrile Rubber Sheet And Tubes
IS standards

Nitrile Rubber Sheet And Tubes

Price on request
GJ
SRI BHAVANI CERAMIC PRIVATE LIMITED· Bharuch