| Place of origin | Ranga Reddi, TG, India |
| Inputs | Speed Sensor (2 inputs for redundancy), Digital inputs (optically isolated, reverse polarity, surge protected, operating at 72VDC). |
| Display | 20-character x 4-line Vacuum Fluorescent Display (VFD) for engine parameters, fault messages, and diagnostics. |
| Speed Settings | 8 different speed settings selectable by Notch from Driver Desk. |
| Display Parameters | Notch Position, Engine RPM, Fuel Rack Position, Booster (Turbo) Air Pressure, Lube Oil Pressure, Fuel Oil Pressure, Load Control Position. |
| Accuracy Of Control | ±3 RPM of desired Engine RPM for the notch. |
| Power Supply Voltage | Diesel Electric Locos – 40VDC to 140VDC. 18VDC for 0.8 seconds during cranking. |
| Communication Interface | RS 485 for communication with locomotive systems, RS 232 for PC/Laptop interface. |
| Speed Sensing Mechanism | 1. Tacho generator 2. Speed Sensor mounted on Engine |
| Actuator Unit Rack Travel | 34 mm (adjustable) |
| Pressure Sensor Range / Accuracy | Lube Oil Pressure: 0 to 10 kg/cm², Fuel Oil Pressure: 0 to 10 kg/cm², Booster (Turbo) Air Pressure: 0 to 10 kg/cm². |